Ventilation
Vents are designed to circulate air throughout your building by installing
roof turbine vents you are reducing a possibility of condensation in your
building.
Roof vents come in 2 parts:
The first part
is the vent adaptor, which is specifically designed to attach to the
special configuration of your building (see diagram below).
The second part is a turbine vent which attaches to the top of the
vent adaptor (see illustration below).

To install turbine vent adaptors on Q or S models buildings, you locate the
center of the building and mark your vent adaptor collar as illustration shows
below.

Remove vent
adaptor, drilling a pilot hole, then cut out around marked area on both sides
of rib. Important: Do not cut out ribs.

Caulk the bottom of the vent adaptor with clear silicon caulking. Place vent
adaptor over the hole you just cut. Drill a hole on top of vent adaptor on
both sides of the hole using bolts supplied with your building. Then tighten
the adaptor down. This should secure the vent adaptor.
For a more secure fit, drill four corners and insert bolts. Then attach the
interior braced turbine vent on top of the vent adaptor with self tapping
screws.
To install turbine vents in A model building, use same procedure as above
except do not install on peak panel in center of the arch. Vent must be installed
on straight roof panel.
|