Curved Angles

The dimensions
for the inner curved angle for your building are 1/2" x 4.5" and the outer curved
angle are 3 1/2" x 4" . They are used together to accept your end walls. It
is easier to install the curved angles on the first arch on the ground before
it is raised.

If you purchased our end walls, you will receive an inner and outer curved
angle set. Install the inner curved angle under the lip of the arch and the
outer curved angle over the lip of the arch at the same time (as shown in
the illustration above).
Note: On A model buildings overlap the curved angles by 1 bolt hole, and on
S and Q model buildings overlap the curved angles by 2 bolt holes.
Insert
drift pins from bottom side through holes of the inner angle and outer angle
and arch at both ends. This procedure aligns all bolt holes. Insert bolts
in all holes and finger tighten. Once all bolts are in, then tighten the bolts.
Your last set of curved angles will be attached while in the air.
|