u.s. buildings
home

Delivery and Storage

pre-building

building assembly

finishes & customization

post-building

downloads

contact us

dealer opportunitiesemployment opportunities
Customer Support

[ Arches | Curved Angles | Strapping | FAQ's ]

Curved Angles

The dimensions for the inner curved angle for your building are 1/2" x 4.5" and the outer curved angle are 3 1/2" x 4" . They are used together to accept your end walls. It is easier to install the curved angles on the first arch on the ground before it is raised.



If you purchased our end walls, you will receive an inner and outer curved angle set. Install the inner curved angle under the lip of the arch and the outer curved angle over the lip of the arch at the same time (as shown in the illustration above).

Note: On A model buildings overlap the curved angles by 1 bolt hole, and on S and Q model buildings overlap the curved angles by 2 bolt holes.

Insert drift pins from bottom side through holes of the inner angle and outer angle and arch at both ends. This procedure aligns all bolt holes. Insert bolts in all holes and finger tighten. Once all bolts are in, then tighten the bolts. Your last set of curved angles will be attached while in the air.





BACK TO TOP


Copyright ©2001 U.S. Buildings Licensing, LLC All Rights Reserved